Gorad Calibration & MSA · Quality

Gauges you can trust, studies you can defend

Make sure the tools you measure with can be trusted. Every gauge is listed with its calibration due date, failed gauges are taken out of use, and studies show whether your measurements are reliable.

The problem

Calibration dates live in a spreadsheet, an overdue gauge is still in use, and Gauge R&R studies are done once and lost.

Early access

Built and tested in software, not yet proven on a plant line. Available to pilot plants.

How it works

Calibration & MSA, step by step

  1. RegisteredA new gauge that has never been calibrated counts as overdue from the day it is registered.
  2. In serviceAfter a passing calibration, the gauge is usable until its next due date.
  3. DueFrom 14 days before the due date (adjustable), quality gets a reminder. The gauge is still usable.
  4. OverdueAfter the due date the gauge is not usable, and SPC knows it.
  5. Failed, quarantinedA failed calibration takes the gauge out of use. A passing calibration alone does not bring it back: quality has to return it to service.
Registerednever calibratedno calibration yetIn serviceusableDueusable · reminderOverduenot usable14 daysdue datecalibration failsQuarantinedfailed · not usablepass, then quality returns it to service
What it does

What Calibration & MSA does

Gauge register

Every gauge with its calibrations, as-found and as-left values and certificates.

Due list

Gauges due and overdue, with reminders to quality before the date.

Quarantine

A failed calibration takes the gauge out of use until quality puts it back.

Gauge R&R

Crossed studies with ANOVA or average-and-range: %GRR, %EV, %AV, number of distinct categories and a verdict.

Shared with SPC

SPC knows when a gauge is not usable.

Reports

Ready to share

Gauge record, register, due list and study, in PDF and Excel.

Gorad Calibration & MSA screen with demo data
Real screen · demo data
Advantages

What changes with Calibration & MSA

No overdue gauge in use by accident

Due dates are tracked and quality is reminded before they pass.

Failed gauges taken out of use

A failed calibration quarantines the gauge until quality puts it back.

Gauge R&R without spreadsheets

Set up the study, enter readings, and get the result and verdict.

SPC knows

SPC is told when a gauge is not usable.

Certificates in one place

Every calibration with its certificate, as-found and as-left values.

Rules it keeps

Built to stay honest

These rules are part of the app, not settings.

  • A gauge that has never been calibrated is overdue from the day it is registered.
  • A passing calibration never lifts a quarantine by itself.
  • Gauge R&R follows the AIAG MSA reference behaviour. It is a statistical aid, not a certification.
On the platform

Works with

  • Same login, roles and audit trail as every Gorad app
  • Runs inside your plant, with offline licensing
Terms used on this page

In plain language

More terms in the glossary.

Calibration
Checking a gauge against a known reference and recording how far off it is.
MSA
Measurement system analysis: checking whether your way of measuring is precise enough to trust.
Gauge R&R
A study of how much measurement variation comes from the gauge (repeatability) and from the people using it (reproducibility).
%GRR
The share of variation caused by the measurement system. Under 10 % is acceptable, 10–30 % marginal, over 30 % unacceptable.
ndc
Number of distinct categories: how many groups of parts the measurement system can reliably tell apart. At least 5 is expected.
Quarantine
Taking something out of use until it is checked and released.
Questions

About Calibration & MSA

What happens when a calibration fails?

The gauge is quarantined. A later passing calibration does not release it by itself; quality must return it to service.

Which Gauge R&R methods are used?

ANOVA and the average-and-range method, following the AIAG MSA reference behaviour.

Is the Gauge R&R result a certification?

No. It is a statistical aid to decide whether a measurement system is good enough.

What about a gauge that has never been calibrated?

It counts as overdue from the day it is registered.

See Calibration & MSA with your data

Tell us how you handle this today, and we will show you how Gorad Calibration & MSA would fit.