Gorad Connect · Early access

Get clean machine data out of the PLC

Your machines already know how many parts they made, when they stopped and why. Gorad Connect reads that from your PLCs and meters and passes it on, so OEE, quality and maintenance run on real data.

Why Gorad Connect

Machine data without the manual work

No more manual logging

Counts, stops and alarms are read straight from the machine, as they happen.

Nothing lost when the network drops

Readings are kept on the gateway and sent once the network is back.

Safe to connect

Read-only by default, and never part of the inspection safety path.

Map once, use everywhere

Raw PLC values become standard events that every app and your own systems understand.

Works with machines you have

Modbus TCP, Siemens S7 and OPC UA, so no new controllers are needed.

Set up in the browser

Find tags, map them and check live values on screen. No programming.

How it works

Read, translate, keep, deliver

When the link to the brokerBroker A message hub (MQTT) that passes events from machines to the apps that need them. goes down, Connect keeps every reading on the gateway and sends it when the link returns. That is store and forwardStore and forward Data is kept safely on the gateway while the network is down, and sent when it comes back..

  1. ReadThe gateway reads tags from your PLCs and meters on a schedule you set.
  2. TranslateRaw values become standard events: a machine state, a part count, a measurement, an alarm.
  3. KeepEvery reading goes into a local buffer first, so a network drop loses nothing.
  4. DeliverEvents go to the apps and to your own systems, in the same clean format.
PLCMeterPLCGorad Connecttags → events0 events queuedBrokerSPC · OEE · your systems
Network up · events delivered
What it does

Talks to the machines you already have

Protocol

Modbus TCPModbus TCP A simple, widely used way for PLCs and devices to exchange data over a network.

Holding and input registers, coils and discrete inputs.

Protocol

Siemens S7Siemens S7 The communication protocol used by Siemens S7 PLCs.

Read data block addresses, and import tags from a TIA Portal export.

Protocol

OPC UAOPC UA A modern, vendor-neutral standard for reading data from industrial machines and controllers.

Connects as a client to PLCs and servers on your network.

Not available today: EtherNet/IP, and Connect acting as an OPC UA server.

Standard events

Tags in, meaningful events out

You map raw tagsTag A named value inside a PLC, such as a part counter or a machine state. once. Every app, and any system that reads from the broker, gets the same clean eventsEvent A clean, standard message such as “machine stopped” or “part counted”, made from raw PLC tags..

machine.state

Running, idle, stopped or faulted, with the time it changed.

production.count

Good and total part counts for OEE and shift reports.

measurement

Process values for SPC and trend charts.

alarm

Machine alarms with their state, for Andon and maintenance.

Set up

Configured from the browser

  • Connections and a catalogue of tags
  • Look inside the PLC from the browser to find the right tags
  • Map tags to events, and check live values on the spot
  • Dead letters: events that could not be delivered, ready for review
Rules it keeps

Built to be safe on a running line

Read-only by default

Writing a value back to a machine must be configured on purpose, and every write is audited.

Never on the safety path

Connect is never part of the inspection result sent to the PLC. That runs on the Vision station itself.

Buffer first

Every reading is stored locally before it is sent, so a network drop cannot lose it.

Nothing silently dropped

Events that still cannot be delivered are kept as dead letters for review.

Bad readings say so

A bad or stale reading is sent with its quality marked, never as a good value.

On the platform

Works with

Connect is the data source for these apps. Use it on its own, or as the first step towards them.

Machine builder or integrator? Connect can ship on its own as the data gateway for your machines. See how partnering works.

Questions

About Gorad Connect

Will Connect change anything on our PLC?

No. It only reads by default. Writing a value back has to be set up on purpose for a specific tag, and every write is recorded.

What happens when the network goes down?

Readings are kept on the gateway and sent when the network returns. Anything that still cannot be delivered is kept for review, not thrown away.

Do we need an MQTT broker?

No. With a broker, events go through it to every app and to your own systems. Without one, the gateway sends events straight to the Gorad server.

Can our own systems use the data?

Yes. Events use a standard format on the broker, so your MES, dashboards or scripts can read them too.

Which PLCs does it support?

PLCs and meters that speak Modbus TCP, Siemens S7 or OPC UA. EtherNet/IP is not available today, and Connect does not act as an OPC UA server.

Get your machine data out of the PLC

Tell us which machines and PLCs you have, and we will show you what Connect would read.